Read an integer parameter from a configuration file
#include <photon/PxProto.h>
int PxConfigReadInt( const char *section,
const char *entry,
int dflt,
int *value );
PxConfigReadInt() reads an integer parameter from the specified section and entry of the configuration file and stores it in *value.
If section is NULL, the function reads the value from entry in the current section. If the required section or entry doesn't exist, the default value is stored in *value.
The value can be signed. The characters after the sign determine the base:
| Character(s): | Base: |
|---|---|
| 0x or 0X | Hexadecimal |
| 0 | Octal |
| Other digits | Decimal |
If the entry doesn't contain a valid int, the default value dflt is stored in *value.
Pt_TRUE if the required section/entry exists and the given value is valid, otherwise Pt_FALSE.
Photon
| Safety: | |
|---|---|
| Interrupt handler | No |
| Signal handler | No |
| Thread | No |
PxConfigOpen(), PxConfigReadBool(), PxConfigReadChar(), PxConfigReadLong(), PxConfigReadShort(), PxConfigReadString(), PxConfigWriteBool(), PxConfigWriteChar(), PxConfigWriteInt(), PxConfigWriteLong(), PxConfigWriteShort(), PxConfigWriteString()